|
Autor |
Wiadomość |
Arczer34
Użytkownik
Rocznik: 2010
Silnik cm3: 3.0
Skrzynia: Tiptronic
Zasilanie: ON
Imię: Marek
Jeżdzę: A8 3.0 L
Dołączył: 12 Wrz 2012 Posty: 48 Skąd: UK
|
Wysłany: 2012-10-06, 17:50
|
|
|
Witam wiec moze ktos mi powie jakie powinno byc kodowanie tylnego panela klimatyzacji bo u mnie sa tylko zera i wydaje mi sie ze tu moze byc problem
[ Dodano: 2012-10-06, 21:19 ]
Dzis po sprawdzeniu i po innych pracach pokazaly sie takie wiadomosci
Monday,17,September,2012,20:16:08:36838
VCDS Version: Release 10.6.3
Data version: 20101206
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Address 08: Auto HVAC Labels: None
Control Module Part Number: 4E0 910 043 HW: 4E0 820 043 A
Component and/or Version: KLIMAAUTOMAT 015 0240
Software Coding: 0020577
Work Shop Code: WSC 02311 785 00200
VCID: DAB00EEC6C99
5 Faults Found:
01851 - Position Sensor; Defrost/Upper Body Shut-Off Flap Motor; Right Front (G317)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 3
Fault Frequency: 3
Reset counter: 6
Mileage: 223649 km
Time Indication: 0
Date: 2012.09.15
Time: 19:40:22
Freeze Frame:
Voltage: 13.90 V
(no units): 202.0
(no units): 255.0
00735 - Potentiometer in Positioning Motor for Air recirculation Flap (G143)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 3
Fault Frequency: 2
Reset counter: 6
Mileage: 223649 km
Time Indication: 0
Date: 2012.09.15
Time: 20:06:08
Freeze Frame:
Voltage: 14.30 V
(no units): 198.0
(no units): 255.0
00716 - Air recirculation Flap Positioning Motor (V113)
003 - Mechanical Failure - Intermittent
Freeze Frame:
Fault Status: 00100011
Fault Priority: 3
Fault Frequency: 2
Reset counter: 6
Mileage: 223650 km
Time Indication: 0
Date: 2012.09.16
Time: 18:25:48
Freeze Frame:
Voltage: 14.20 V
Temperature: 22.0°C
(no units): 189.0
(no units): 87.0
Temperature: -100.0°C
00728 - Potentiometer in Positioning Motor for Left-Hand Central Vent (G136)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 3
Fault Frequency: 3
Reset counter: 6
Mileage: 223650 km
Time Indication: 0
Date: 2012.09.16
Time: 18:37:47
Freeze Frame:
Voltage: 14.30 V
(no units): 0.0
(no units): 0.0
00729 - Potentiometer in Positioning Motor for Right-Hand Central Vent (G137)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 3
Fault Frequency: 1
Reset counter: 6
Mileage: 223650 km
Time Indication: 0
Date: 2012.09.17
Time: 19:12:50
Freeze Frame:
Voltage: 10.10 V
(no units): 214.0
(no units): 255.0
Sunday,30,September,2012,18:49:34:36838
VCDS Version: Release 10.6.3
Data version: 20101206
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Adaptation Channel 001:
Stored value 5964
N/A
N/A
N/A
N/A
Sunday,30,September,2012,19:01:50:36838
VCDS Version: Release 10.6.3
Data version: 20101206
19:01:43
Open Circuit IF-Wire Status
Sunday,30,September,2012,19:04:49:36838
VCDS Version: Release 10.6.3
Data version: 20101206
19:04:47
OK Status TV-Antenna 1
0.050 A Current TV-Antenna 1
OK Status TV-Antenna 2
0.040 A Current TV-Antenna 2
OK Status TV-Antenna 3
0.050 A Current TV-Antenna 3
OK Status TV-Antenna 4
OK Status Video-Out
Yes Status Tuner V1
Yes Status Tuner V2
Sunday,30,September,2012,19:32:57:36838
VCDS Version: Release 10.6.3
Data version: 20101206
Address 08: Auto HVAC Labels: NONE
Control Module Part Number: 4E0 910 043 HW: 4E0 820 043 A
Component and/or Version: KLIMAAUTOMAT 015 0240
Software Coding: 0020577
Work Shop Code: WSC 02311 785 00200
VCID: DAB00EEC6C99
4 Faults Found:
01087 - Basic Setting Not Performed
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 2
Fault Frequency: 1
Reset counter: 231
Mileage: 223658 km
Time Indication: 0
Date: 2012.09.30
Time: 19:30:28
01869 - Left Rear Cold / Warm Air Outlet Motor Position Sensor (G351)
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 3
Fault Frequency: 1
Reset counter: 231
Mileage: 223658 km
Time Indication: 0
Date: 2012.09.30
Time: 19:30:28
Freeze Frame:
Voltage: 12.30 V
(no units): 199.0
(no units): 17.0
00735 - Potentiometer in Positioning Motor for Air recirculation Flap (G143)
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 3
Fault Frequency: 1
Reset counter: 231
Mileage: 223658 km
Time Indication: 0
Date: 2012.09.30
Time: 19:30:50
Freeze Frame:
Voltage: 12.30 V
(no units): 198.0
(no units): 255.0
00731 - Potentiometer in Positioning Motor for Left-Hand Footwell Flap (G139)
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 3
Fault Frequency: 1
Reset counter: 231
Mileage: 223658 km
Time Indication: 0
Date: 2012.09.30
Time: 19:30:50
Freeze Frame:
Voltage: 12.30 V
(no units): 13.0
(no units): 255.0
Saturday,06,October,2012,19:49:08:36838
VCDS Version: Release 10.6.3
Data version: 20101206
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Address 08: Auto HVAC Labels: NONE
Control Module Part Number: 4E0 910 043 HW: 4E0 820 043 A
Component and/or Version: KLIMAAUTOMAT 015 0240
Software Coding: 0020577
Work Shop Code: WSC 02311 785 00200
VCID: DAB00EEC6C99
2 Faults Found:
01087 - Basic Setting Not Performed
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 2
Fault Frequency: 1
Reset counter: 234
Mileage: 223665 km
Time Indication: 0
Date: 2012.10.06
Time: 19:47:41
01869 - Left Rear Cold / Warm Air Outlet Motor Position Sensor (G351)
005 - No or Incorrect Basic Setting / Adaptation
Freeze Frame:
Fault Status: 01100101
Fault Priority: 3
Fault Frequency: 1
Reset counter: 234
Mileage: 223665 km
Time Indication: 0
Date: 2012.10.06
Time: 19:47:41
Freeze Frame:
Voltage: 14.20 V
(no units): 149.0
(no units): 17.0
Moze cos po tym ktos dojdzie i pomoze mi bo nie moge sie z tym uporac
[ Dodano: 2012-10-09, 06:31 ]
Witam nie ma chetnych mi pomoc z tymi przypadlosciami kolego Wolek czy moge cie prosic o podanie jesli jest taka mozliwosc coding2 w sterowniku klimatyzacji bo nie mam mozliwosci wejscia vcds nie pokazuje podpowiedzi a nie wiem gdzie go wygenerowac
[ Dodano: 2012-10-12, 20:24 ]
Tu oczywiscie cisza spoko
[ Dodano: 2012-12-20, 18:34 ]
Czy nikt tu nie zaglada potrzebuje kodowania tylnego panelu jesli takowe jest bo u mnie vcds pokazuje tylko 0000000 w tylnym |
|
|
|
|
|
|
|
rav85
Moje A8
Rocznik: 2003
Silnik cm3: 4.2
Skrzynia: Tiptronic
Zasilanie: PB
Imię: Marek
Jeżdzę: Huracan Perf&Maclaren600LT
Pomógł: 4 razy Dołączył: 26 Sty 2015 Posty: 258 Skąd: Warszawa
|
Wysłany: 2015-08-11, 13:36
|
|
|
ja się podepnę pod temat bo ostatnio wywala mi pełno rożnych błędów Intermittent
nie wiem czy nie jest to wina sterownika akumulatora?
akumulator nowy varta silver 110 zakodowany w sterowniku i po jakim czasie co parę dni wywala błąd
02256 - Quiescent Current
001 - Upper Limit Exceeded - Intermittent |
|
|
|
|
|
|
|
orkaskawina
Moje A8
Rocznik: 2008
Silnik cm3: 6.0
Skrzynia: Tiptronic F1
Zasilanie: PB
Imię: Krzysztof
Jeżdzę: A8 D3 W12 A6 C5 2.5 TDI
Pomógł: 21 razy Wiek: 47 Dołączył: 25 Lis 2012 Posty: 471 Skąd: Skawina
|
Wysłany: 2015-08-11, 19:14
|
|
|
rav85 napisał/a: | 02256 - Quiescent Current |
Coś nie do końca ci usypia i podbiera z aku prąd i stąd komunikat o przekroczonym progu prądu spoczynkowego. |
_________________ Odis Ellsa 5.3 baza 2016
http://chomikuj.pl/orkaskawina
VCDS , ODIS-s -e |
|
|
|
|
|
Nie możesz pisać nowych tematów Nie możesz odpowiadać w tematach Nie możesz zmieniać swoich postów Nie możesz usuwać swoich postów Nie możesz głosować w ankietach Nie możesz załączać plików na tym forum Możesz ściągać załączniki na tym forum
|
Dodaj temat do Ulubionych Wersja do druku
|
Powered by phpBB modified by Przemo © 2003 phpBB Group
Prywatność. |
|
|